CLDJT - NICKEL-CADIUM SEALED CELL BATTERY
- MSDS: CLDJT
- Manufacturer: AVEX ELECTRONICS CORP
- Product Name: NICKEL-CADIUM SEALED CELL BATTERY
- National Stock Number: -
Product Identification
Product ID:NICKEL-CADIUM SEALED CELL BATTERY
MSDS Date:02/19/1999
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CLDJT
Responsible Party
BENSALEM, PA 19020-4510
US
Emergency Phone: 215-638-1515
Info Phone: 215-638-1515
Preparer: MICHAEL BAIR
Cage: 58414
Contractor
Telephone: 215-638-1515
Cage: 58414
Ingredients
CADMIUM. (PRESENT AS CADMIUM, CADMIUM HYDROXIDE, CADMIUM
CAS: 7440-43-9
RTECS: EU9800000
OSHA PEL SEE OTHER INFO.
ACGIH TLV: SEE OTHER INFO.
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
NICKEL. (PRESENT AS NICKEL, NICKEL HYROXIDE, NICKEL OXIDE)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1.0 AS NI
ACGIH TLV: 1.0 AS NI
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:CANCER HAZARD. CONTAINS CADMIUM AND
NICKEL, WHICH ARE LISTED AS LUNG, KIDNEY AND NASAL CARCINOGENS .
CONTAINS CADMIUM WHICH APPEARS ON THE NAVY OCCUPATIONAL CHEMICAL
REPRODUCTIVE HAZARDS LIST. S EEK CONSULTATION FROM APPROPRIATE
HEALTH PROFESSIONALS CONCERNING SAFE HANDLING AND EXPOSURE
INFORMATION .
Explanation of Carcinogenicity:CADMIUM, CADMIUM HYDROXIDE, CADMIUM
OXIDE: IARC GROUP 1, VOLUME 58, PAGE 119, 1993. NTP KNOWN HUMAN
CARCINOGEN, NTP-9TH ANNUAL REPORT ON CARCINOGENS, 2000. NICKEL,
NICKEL HYDROXIDE, NICKEL OXIDE: IAR C GROUP 1, VOLUME 49, PAGE 257,
1990. NTP ANTICIPATED HUMAN CARCINOGEN, NTP-9TH ANNUAL REPORT ON
CARCINOGENS, 2000.
Effects of Overexposure:IRRITATION OF NOSE AND THROAT, SWEATING,
CHILLS, SHORTNESS OF BREATH, WEAKNESS, LOCAL DERMATITIS, NAUSEA,
COUGHING, CHEST PAINS.
Medical Cond Aggravated by Exposure:RESPIRATORY SYSTEM DISORDERS,
PROSTATE DISORDERS, LIVER AND KIDNEY DISORDERS.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE, SEE PHYSICAN. INGESTION:
INDUCE VOMITING IF CONSCIOUS, SEE PHYSICIAN. SKIN OR EYES: FLUSH
WITH WATER FOR 15 MINUTES. SEE PHYSICIAN IF SYMPTOMS DEVELOP.
Fire Fighting
Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:DRY CHEMICAL, CO2, WATER.
Fire Fighting Procedures:USE NIOSH-APPROVED SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE CLOTHING IF INVOLVED IN A FIRE.
Unusual Fire/Explosion Hazard:NOT APPLICABLE.
Accidental Release
Spill Release Procedures:CONTAIN THE SPILL. COLLECT SPILLED MATERIAL
AND PLACE IT IN A PLASTIC-LINED CONTAINER. HEPA VACUUMING IS
PREFERRED. FLUSH SPILL AREA WITH WATER.
Handling
Handling and Storage Precautions:WEAR NIOSH-APPROVED DUST MASK OR
RESPIRATOR, IMPERVIOUS GLOVES AND SAFETY GLASSES OR GOGGLES. KEEP
CONTAINER CLOSED; AVOID CONTACT WITH CLOTHING. AVOID GENERATING
DUST.
Exposure Controls
Respiratory Protection:NIOSH-APPROVED FOR DUSTS.
Ventilation:LOCAL EXHAUST, MECHANICAL (GENERAL):YES. SPECIAL: NA.
OTHER: MAINTAIN OSHA PEL.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEMCIAL SAFETY GOGGLES .
Other Protective Equipment:EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA .
Work Hygienic Practices:DO NOT WEAR CONTAMINATED CLOTHING HOME. SHOWER
AND CHANGE OR WEAR COVERALLS. KEEP TOBACCO AND FOOD AWAY FROM WORK
AREA.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:1.6
Evaporation Rate & Reference:NA
Appearance and Odor:NO APPEARANCE OR ODOR SPECIFIED BY MANUFACTURER .
Stability
Stability Indicator/Materials to Avoid:YES
NA
Stability Condition to Avoid:GENERAL STORAGE PROCEDURES FOR HAZARDOUS
MATERIALS ARE ACCEPTABLE.
Hazardous Decomposition Products:METAL OXIDE FUMES MAY BE EVOLVED AT
TEMPERATURES ABOVE MELTING POINT.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL LAWS. IF DISCARDED, TREAT AS HAZARDOUS WASTE.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.